For posts where the outside of the post is accessible. This fitting is threaded and can be tensioned.
|
|
For posts that inside face fitting only is required. This fitting is threaded and can be tensioned.
|
|
For posts that require fitting to inside face of the post. This fitting cannot be tensioned.
|
|
STEP 2 - MEASURE YOUR POSTS
|
|
AA (outside - outside)
BB (inside - inside)
BC (inside - inside)
AB (outside - inside)
AC (outside - inside)
|
|
STEP 3 - ORDER YOUR REQUIREMENTS
Simply provide your measurement to your local Midcoast branch. As this is a custom
manufactured product, allow 2 to 3 days for production.
|
|
STEP 4 - INSTALL
The installation of your new balustrade is simple. First mark the location of your holes.
|
|

1) Drill a 9 mm hole completely through your post.
2) Thread the wire through all posts, attach the end fittings and tension using an Allen key.
|
|

1) Drill a 3 mm pilot hole on inside face of post, being careful not to drill right through your post.
2) Screw in the eyelet provided and attach fitting.
3) Tension with two spanners.
|
|
Important: All fittings (A, B and C) should be tensioned to 10 mm deflection and definitely not over tensioned as this may damage your posts.
|
|
STEP 5 - ADMIRE YOUR HANDYWORK!
|
|
|
|
|
|